EDID Viewer
Decode and analyze 128 byte EDID binary data to view supported timings, texts, and settings.
Frequently asked questions
How do I get the EDID of my monitor?
On Linux it is a file under /sys/class/drm/, for example /sys/class/drm/card0-HDMI-A-1/edid. You can drop that file here directly. On Windows, the command reg query HKLM\SYSTEM\CurrentControlSet\Enum\DISPLAY /s /v EDID prints every stored EDID as hex text that you paste into the text field.
What does an invalid checksum mean?
The last byte is chosen so that the sum of all 128 bytes is divisible by 256. If it is not, the EDID was cut off while reading or is damaged in the monitor. Typical results are wrong resolutions or a black screen behind adapters and HDMI switches.
Are extension blocks such as CEA-861 decoded?
The 128-byte base block is decoded completely, and the tool shows how many extension blocks follow. The contents of a CEA block, such as HDMI audio formats, are not broken down yet.
How does this tool work?
Decode and analyze monitor EDID binary data directly in your browser.
Paste the EDID hex data or upload a .bin file. The tool parses the 128 bytes according to the EDID specification into vendor info, basic display parameters, color characteristics, supported timings, and descriptors, and visualizes the timing blocks graphically.
Where are my data processed?
Only in your browser. Your data is not sent to any server.
The tool calculates and converts with JavaScript right on your device. Input and files are not sent to us or anyone else. You can check this yourself: load the page, disconnect from the internet, and the tool keeps working in the open tab.